The LabAssay™ Series is a collection of biochemical assay kits for analyzing samples from humans, mice, and other animals. Since analyses are performed in microtiter plates, many samples can be concurrently evaluated, and only small sample amounts are needed.
※For Research Use Only, Not for Diagnostic Use
- 1. LabAssay™ Ammonia
- 2. LabAssay™ ALP
- 3. LabAssay™ Cholesterol
- 4. LabAssay™ Creatineine
- 5. LabAssay™ Glucose
- 6. LabAssay™ NEFA
- 7. LabAssay™ Phospholipid
- 8. LabAssay™ Tryglyceride
- 9. Reagents for Adiposity & Diabetes Research
- LabAssay™ Series (1,695KB/6p)
1. LabAssay™ Ammonia
Ammonia is mainly produced in the intestine or the kidney. Ammonia produced in the body is converted to urea through a series of reactions known as the urea cycle in the liver and eliminated through urine.
Assay Principle (Modified Fujii-Okuda Method)
Ammonia is converted to Dioxydiphenylamine by the reaction of Phenol and Sodium Pentacyanonitrosyl ferrate(III). A reaction of the Dioxydiphenylamine with Sodium Hypochlorite produces Indophenol ,which pigments blue, under alkaline conditions. LabAssay ™ Ammonia is a kit used for the quantitative determination of ammonia nitrogen in samples by measuring absorbance of the blue color.
Kit Contents Standard Curve
|
Performance
Standard curve range | 100~400μg/dL(μg/100mL) |
Measurement time | approx. 70 minutes |
Amount of sample | 70μL |
Measurement wavelength | 630nm |
Product list
Product Name | Grade | Pkg. Size | Wako Cat. No. | Storage Condition |
---|---|---|---|---|
LabAssay™ Ammonia | for Cellbiology | 700 tests | 295-78901 | Keep at 2-10℃ |
※Not available for sale in India.
2. LabAssay™ ALP
Alkaline Phosphatase (ALP) is an enzyme distributed in a variety of tissues such as the liver, bone and small intestines in animals. Especially, it is used one of the Osteogenesis Markers in bone metabolism research area.
Assay Principle (Alkaline Phosphatase activity assay with p-Nitrophenyl Phosphate as a substrate)
p-Nitrophenylphosphate is hydrolyzed into p-Nitrophenol in the presence of Alkaline Phosphatase(ALP). LabAssay™ ALP is a kit designed to determine Alkaline Phosphatase activity in samples by measuring the amount of p-Nitrophenol released by p-Nitrophenylphosphate as a phosphatase substrate.
Kit Contents Standard Curve
|
Performance
Standard curve range | 0.0652~0.5mmol/L |
Measurement time | approx. 20 minutes |
Amount of sample | 20μL |
Measurement wavelength | 405nm |
Reference
1) Ito, S. et al.: J. Pharmacol. Exp. Ther., 333, 341 (2010). ※Extraction liquid of mouse kidney
2) Iwakura, T. et al.: J. Orthop. Res., 27, 208 (2009). ※Extraction liquid of human culture cells
3) Furuya, Y. et al.: J. Biol. Chem., 286, 37023 (2011). ※Mouse serum
4) Itoh, T. et al.: J. Biol. Chem., 284, 19272 (2009). ※Extraction liquid of mouse culture cells
Product List
Product Name | Grade | Pkg. Size | Wako Cat. No. | Storage Condition |
---|---|---|---|---|
LabAssay™ ALP | for Cellbiology | 900 tests | 291-58601 | Keep at 2-10℃ |
3. LabAssay™ Cholesterol
Cholesterol, a major component of cell membranes and the starting material in steroid synthesis in many animals, is a factor behind arteriosclerosis and other vascular diseases.
Assay Principle (Cholesterol Oxidase・DAOS method)
Hydrogen peroxide produced by a reaction of cholesterol and cholesterol oxidase let N-Ethyl-N-(2-hydroxy-3-sulfopropyl)-3,5-dimethoxyaniline sodium salt(DAOS)and 4-Aminoantipyrin oxidize and condensate. LabAssay™ Cholesterol is a kit to determine total cholesterol by measuring absorbance of the blue color which is generated by the oxidative condensation reaction.
Kit Contents Standard Curve
|
Performance
Standard curve range | 50~592.2mg/dL(mg/100mL) |
Measurement time | approx. 10 minutes |
Amount of sample | 2μL |
Measurement wavelength | 600nm(Main), 700nm(Sub) |
Reference
1) Wu, S. Y. et al.: Acta Pharmacol. Sin., 30, 202 (2009). ※Mouse plasma
2) Uchida, K. et al.: Exp. Anim., 58, 181 (2009). ※Extraction liquid of mouse tissue
3) Ushio, M. et al.: Am. J. Physiol. Endocrinol. Metab., 305, E293 (2013). ※Extraction liquid of mouse tissue
4) Kobayashi, Y. et al.: Biosci. Biotechnol. Biochem., 74, 2385 (2010). ※ Extraction liquid of rat tissue
Product List
Product Name | Grade | Pkg. Size | Wako Cat. No. | Storage Condition |
---|---|---|---|---|
LabAssay™ Cholesterol | for Cellbiology | 1,000 tests | 294-65801 | Keep at 2-10℃ |
※Not available for sale i n the US.
4. LabAssay™ Creatineline
Creatinine is a metabolite which is produced by creatine phosphate directly or dehydration of creatine in muscle and nerve. It is excreted from the body through kidney glomerular filtration.
Assay Principle (Jaffé method)
LabAssay™ Creatinine can be used to measure the creatinin levels in samples by Jaffe’s reaction where creatinine produces quantitatively an orange color with picric acid in alkaline condition.
Kit Contents Standard Curve
|
Performance
Standard curve range | 2.5~10mg/dL(mg/100mL) |
Measurement time | approx. 40 minutes |
Amount of sample | 50μL |
Measurement wavelength | 520nm |
Reference
1) Aranami, F. et al.: J. Med. Invest., 57, 95 (2010). ※ Mouse plasma and urine
2) Toyama, K. et al.: Br. J. Pharmacol., 166, 1183 (2012). ※Mouse plasma
3) Matsumoto, A. et al.: Environ. Health Prev. Med., 15, 211 (2010). ※Human urine
4) Nasrin, S. et al.: J. Pharmacol. Sci., 122, 270 (2013). ※Rat urine
Product List
Product Name | Grade | Pkg. Size | Wako Cat. No. | Storage Condition |
---|---|---|---|---|
LabAssay™ Creatinine | for Cellbiology | 500 tests | 290-65901 | Keep at 2-10℃ |
※Not available for sale in Europe.
5. LabAssay™ Glucose
Sugar is one of the most important sources of energy in biology. It is regulated by various factors within an organism. Glucose converges to a stable ratio of α-form and β-form in solutions.
Assay Principle (Mutarotase・GOD method)
α-D-Glucose is converted to β-D-Glucose by mutarotase. Hydrogen peroxide, which is produced by a reaction between β-D-Glucose and glucose oxidase(GOD), promotes oxidative condensation of phenol with 4-aminoantipyrine quantitatively. LabAssay™ Glucose is a kit used for the quantitative determination of glucose concentrations in samples by measuring absorbance of a red color which is generated by the oxidative condensation reaction.
Kit Contents Standard Curve
|
Performance
Standard curve range | 2.5~10mg/dL(mg/100mL) |
Measurement time | approx. 40 minutes |
Amount of sample | 50μL |
Measurement wavelength | 505nm(Main), 600(Sub) |
Reference
1) Yamashita, Y. et al.: Biosci. Biotechnol. Biochem., 77, 888 (2013). ※Mouse plasma
2) Yamashita, Y. et al.: J. Nutr. Sci., 1, e2 (2012). ※Mouse plasma
3) Wang, W. et al.: J. Renin Angiotensin Aldosterone Syst., 15, 384 (2014). ※Mouse serum
4) Maesako, M. et al.: Neurobiol. Aging, 33, 1011 (2012). ※Mouse serum
Product List
Product Name | Grade | Pkg. Size | Wako Cat. No. | Storage Condition |
---|---|---|---|---|
LabAssay™ Glucose | for Cellbiology | 1,000 tests | 298-65701 | Keep at 2-10℃ |
6. LabAssay™ NEFA
NEFA (Non‐esterified fatty acid) in the blood is transported complexed with an albumin to peripheral tissues. They are important sources of fuel for the peripheral tissues. The concentration of NEFA in the blood is regulated by a release from the adipose tissues, a consumption in the periphral tissues or a take up from the liver.
Assay Principle (ACS・ACOD method)
NEFA (Non‐esterified fatty acid) forms Acyl-CoA in the presence of Acyl-CoA synthetase(ACS). Hydrogen peroxide, which is produced by a reaction between the Acyl-CoA and Acyl-CoA oxidase(ACOD), promotes oxidative condensation of 3-methyl-N-ethyl-N(-β-hydroxyethyl)-aniline(MEHA) with 4-aminoantipyrine. LabAssay™ NEFA can be used for the quantitative determination of NEFA in samples by measuring absorbance of a blue purple color which is generated by the oxidative condensation reaction.
Kit Contents Standard Curve
※Oleic acid 1mEq=1mmol |
Performance
Standard curve range | 0.5~1.97mEq/L |
Measurement time | approx. 20 minutes |
Amount of sample | 4μL |
Measurement wavelength | 550nm |
Reference
1) Wang, F. et al.: J. Mol. Endocrinol., 52, 133 (2014). ※Mouse plasma
2) Kobayashi, Y. et al.: Biosci. Biotechnol. Biochem., 74, 2385 (2010). ※Rat plasma
3) Chang, Y. C. et al.: EMBO Mol. Med., 5, 1165 (2013). ※Mouse plasma
4) Uchida, K. et al.: Exp. Anim., 58, 181 (2009). ※Mouse serum
Product List
Product Name | Grade | Pkg. Size | Wako Cat. No. | Storage Condition |
---|---|---|---|---|
LabAssay™ NEFA | for Cellbiology | 750 tests | 294-63601 | Keep at 2-10℃ |
※Not available for sale in the US and Europe.
7. LabAssay™ Phospholipid
Phospholipids are known as not only as major component of cell membranes but also perform vital functions within the body such as emulsification and absorption of fats or coagulation of blood.
Assay Principle (Choline Oxidase・DAOS method)
Phospholipids are hydrolyzed by Phospholipase D to release hydrogen peroxide. The formed hydrogen peroxide promotes oxidative condensation of N-ethyl-N-(2-hydroxy-3-sulfopropyl)-3,5-dimethoxyaniline sodium salt(DAOS) with 4-aminoantipyrine. LabAssay™ Phospholipid is a kit to determine Phospholipid concentration in samples by measuring absorbance of a blue color which is generated by the oxidative condensation reaction.
Kit Contents Standard Curve
|
Performance
Standard curve range | 150~596.1mg/dL(mg/100mL) |
Measurement time | approx. 10 minutes |
Amount of sample | 2μL |
Measurement wavelength | 600nm(Main), 700(Sub) |
Reference
1) Xu, Q. et al.: Biosci. Biotechnol, Biochem., 77, 1390 (2013). ※Extraction liquid of mouse liver
2) Kuge, H. et al.: J. Biol. Chem., 289, 26783 (2014). ※Liposome
3) Kessler, E. C. et al.: J. Dairy Sci., 97, 5481 (2014). ※Bovine
4) Cheng, L. et al.: Transplantation, 90, 127 (2010). ※Rat
Product List
Product Name | Grade | Pkg. Size | Wako Cat. No. | Storage Condition |
---|---|---|---|---|
LabAssay™Phospholipid | for Cellbiology | 1,300 tests | 296-63801 | Keep at 2-10℃ |
※Not available for sale in the US.
8. LabAssay™ Tryglyceride
Triglycerides are neutral fats consisting of three fatty acids esterified to a glycerol backbone. There are triglycerides, cholesterol, phospholipids, free fatty acids and fat-soluble vitamins as lipid-soluble substances in the blood.
Assay Principle
Triglycerides are converted to glycerol-3-phosphate by lipoprotein lipase and glycerolkinase. Hydrogen peroxide, which is produced by a reaction between the glycerol-3-phosphate and glycerol-3-phosphate oxidase(GPO), promotes oxidative condensation of N-ethyl-N-(2-hydroxy-3-sulfopropyl)-3,5-dimethoxyaniline sodium salt(DAOS) with 4-aminoantipyrine. LabAssay ™ Triglyceride can be used to detect triglycerides concentration in samples by measuring absorbance of a blue color which is generated by the oxidative condensation reaction.
Kit Contents Standard Curve
|
Performance
Standard curve range | 100~888mg/dL(mg/100mL) |
Measurement time | approx. 10 minutes |
Amount of sample | 2μL |
Measurement wavelength | 600nm(Main), 700(Sub) |
Reference
1) Saito, M. et al.: Biosci. Biotechnol. Biochem., 76, 2049 (2012). ※Mouse serum
2) Fujimori, K. et al.: Prostaglandins Other lipid Mediat., 94, 96 (2011). ※Extraction liquid of mouse culture cells
3) Zhou, L. et al.: Am. J. Physiol. Renal Physiol., 305, F1491 (2013). ※Rat plasma
4) Wu, S. Y. et al.: Acta Pharmacol. Sin., 30, 202 (2009). ※Rat plasma
5) Wang, F. et al.: J. Mol. Endocrinol., 52, 133 (2014). ※Rat plasma
6) Kato, H. et al.: J. Hepatol., 60, 1032 (2014). ※Extraction liquid of mouse liver
Product List
Product Name | Grade | Pkg. Size | Wako Cat. No. | Storage Condition |
---|---|---|---|---|
LabAssay™ Triglyceride | for Cellbiology | 1,000 tests | 290-63701 | Keep at 2-10℃ |
9. Reagents for Adiposity & Diabetes Research
Wako offers a wide variety of products for studying Obesity and Diabetes.
Code No. | Product Name | Standard curve range | Grade | Pkg. Size | Storage Condition |
---|---|---|---|---|---|
299-75501 | GLP-1 ELISA Kit Wako, High Sensitive |
0.94~30pmol/L (3.1~100pg/mL ) |
for Diabetes Research | 96 tests | Keep at 2-10℃ |
293-79301 | Active GLP-1 ELISA Kit Wako, Chemiluminescent | 0.123~30pmol/L | for Diabetes Research | 96 tests | Keep at 2-10℃ |
291-59201 | Rat GLP-1 ELISA Kit Wako | 206~50,000pg/mL | for Diabetes Research | 96 tests | Keep at 2-10℃ |
292-60601 | Rat GLP-2 ELISA Kit Wako | 0.137~100ng/mL | for Diabetes Research | 96 tests | Keep at 2-10℃ |
299-73801 | Mouse GIP(Active) ELISA Kit Wako | 7.8~500pg/mL | for Diabetes Research | 96 tests | Keep at 2-10℃ |
292-80001 | Glucagon ELISA Kit Wako | 2.2~143.6pmol/L (7.8~500pg/mL) |
for Diabetes Research | 96 tests | Keep at 2-10℃ |
291-73501 | Mouse/Rat PYY ELISA Kit Wako | 0.15~12.5ng/mL | for Adiposity Research | 96 tests | Keep at 2-10℃ |
295-57401 | Rat C-Peptide ELISA Kit Wako | 1.56~50ng/mL | for Diabetes Research | 96 tests | Keep at 2-10℃ |
297-57601 | Rat Leptin ELISA Kit Wako | 78.1~5,000pg/mL (Non-Plasma、Non-serum) 312.5~20,000pg/mL (Plasma、Serum) |
for Adiposity Research | 96 tests | Keep at 2-10℃ |
ELISA for Measuring Insulin
Code No. | Maker Code | Product Name | Standard curve range | Pkg. Size | Storage Condition |
---|---|---|---|---|---|
637-10629 | AKRIN-010H | Lbis Insulin-Rat (H type) | 0.5 ~100ng/mL | 96 tests | Keep at 2-10℃ |
634-10379 | AKRIN-011H | Lbis Insulin-Mouse (H type) | 0.5 ~100ng/mL | 96 tests | Keep at 2-10℃ |
631-01479 | AKRIN-010T | Lbis Insulin-Rat-T | 0.156 ~10ng/mL | 96 tests | Keep at 2-10℃ |
638-01489 | AKRIN-011T | Lbis Insulin-Mouse-T | 0.156 ~10ng/mL | 96 tests | Keep at 2-10℃ |
631-07199 | AKRIN-010S | Lbis Insulin-Rat (S type) | 0.1 ~10ng/mL | 96 tests | Keep at 2-10℃ |
630-07289 | AKRIN-011S | Lbis Insulin – Mouse (S type) | 78 ~5,000pg/mL | 96 tests | Keep at 2-10℃ |
– | AKRIN-130 | Lbis Insulin-Rat (U-E type) | 39 ~2,500pg/mL | 96 tests | Keep at 2-10℃ |
– | AKRIN-031 | Lbis Insulin-Mouse (U type) | 39 ~2,500pg/mL | 96 tests | Keep at 2-10℃ |
630-24149 | AKRIN-010RU | Lbis Rat Insulin ELISA KIT(RTU) | 100 ~12,000pg/mL | 96 tests | Keep at 2-10℃ |
633-23919 | AKRIN-011RU | Lbis Mouse Insulin ELISA KIT(RTU) | 100 ~12,000pg/mL | 96 tests | Keep at 2-10℃ |
637-01459 | AKRIN-012T | Lbis Insulin-Dog-T | 0.188 ~12ng/mL | 96 tests | Keep at 2-10℃ |
634-01469 | AKRIN-013T | Lbis Insulin-Porcine | 0.188 ~12ng/mL | 96 tests | Keep at 2-10℃ |
– | AKRIN-014T | Lbis Insulin-Monkey-T | 0.156 ~10ng/mL | 96 tests | Keep at 2-10℃ |
Other products : Reagent for Adiposity & Diabetes Research
Code No. | Maker Code | Product Name | Standard curve range | Pkg. Size | Storage Condition |
---|---|---|---|---|---|
630-23049 | AKMPI-111 | Lbis Proinslin Mouse/Rat | 1.47~94.3pg/mL (Standard curve range) 7.35~471.5pg/mL (Amount of a sample:10μL) |
60 tests | Keep at 2-10℃ |
635-07239 | AKRCP-031 | Lbis C-Peptide-Mouse (U type) |
46.9~3,000pg/mL (Standard curve range) 234.5~15,000pg/mL (Amount of a sample:10μL) |
96 tests | Keep at 2-10℃ |
633-07279 | AKRCP-030 | Lbis C-Peptide Rat (U type) |
46.9~3,000pg/mL (Standard curve range) 234.5~15,000pg/mL (Amount of a sample:10μL) |
96 tests | Keep at 2-10℃ |
631-10389 | AKRLP-011 | Lbis Leptin-Mouse | 103~25,000pg/mL (Standard curve range) 20.6~5,000pg/mL (Amount of a sample:10μL) |
96 tests | Keep at 2-10℃ |
638-04309 | AKRAL-121 | Lbis Albumin Mouse ELISA Kit |
50~1,000ng/mL (Standard curve range) |
96 tests | Keep at 2-10℃ |
635-04319 | AKRAL-120 | Lbis Albumin Rat ELISA Kit |
50~1,000ng/mL (Standard curve range) |
96 tests | Keep at 2-10℃ |
639-13749 | AKRGH-010 | Lbis GH-Rat | 31.3~2,000pg/mL (Standard curve range) 313~20,000pg/mL (Amount of a sample:5μL) 62.6~4,000pg/mL (Amount of a sample:25μL) |
96 tests | Keep at 2-10℃ |
630-23929 | AKRLH-010S | Lbis Rat LH ELISA KIT(S type) |
313~10,000pg/mL (Standard curve range) 1.56~50ng/mL (Amount of a sample:10μL) |
96 tests | Keep at 2-10℃ |
633-31729 | AKRTS-010S2 | Lbis TSH-Rat (SⅡtype) |
184~18,000pg/mL (Standard curve range) 0.92~90ng/mL (Amount of a sample:20μL) |
96 tests | Keep at 2-10℃ |
637-15129 | AKMGP-011 | Lbis GLP-1(active) ELISA KIT |
1.56~50pg/mL (Standard curve range) 7.8~250pg/mL (Amount of a sample:10μL) 3.9~125pg/mL (Amount of a sample:20μL) |
96 tests | Keep at 2-10℃ |
638-13079 | AKMAN-011 | Lbis High Molecular Adiponectin-Mouse/Rat |
3.13~200ng/mL (Standard curve range) 78.25~5,000ng/mL (Using sample diluted 25times) |
96 tests | Keep at 2-10℃ |